Mass battery chargers are designed for the toughest conditions for professional, semi-professional and recreational purposes. Even under the most extreme conditions the products from the Mass series operate faultlessly, giving you round-the-clock output when necessary. The sustainability and technologies that underpin the Mass concept have long been proven in practice. With an MTBF of 180,000 hours at full capacity and 24/7 use, the Mass products are ideal for the toughest tasks and any situation that requires a reliable power supply.
Overall dimensions: 170 x 110 x 52 mm Frequency: 50 – 60 Hz Rated secondary voltage: 100 V Rated voltage factor: 1.2 continuous Highest system voltage: 0.72 kV up to 600V 1.44 kV up to 1000V One minute test voltage between primary and secondary: 3kV up to 600V, 6kV up to 1000V Input protection: fuse
Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 5VA Protection degree: IP 50 / IP 20 Inputs: 1 A / 100 V DC Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
mod. CCTA-DIN/G2 Download the the Data-sheet GENERAL FEATURES Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 5VA Protection degree: IP 50 / IP 20 Inputs: 5 A / 500 V AC Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 5VA Protection degree: IP 50 / IP 20 Inputs: 60 mV / 10 V CC Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 5VA Protection degree: IP 50 / IP 20 Inputs: 1 A / 2000 V DC Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 3VA Protection degree: IP 50 / IP 20 Inputs: from 45 un to 55 Hz Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 3VA Protection degree: IP 50 / IP 20 Inputs: from 55 up to 65 Hz Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
Overall dimensions: 4 DIN modules Accuracy: 0.5% Self-consumption: < 3VA Protection degree: IP 50 / IP 20 Inputs: from 350 up to 750 Hz Outputs: 0 - 20 mA DC ; 4 - 20 mA DC 0 - 10 V DC ; 0 - +/-1 V DC
GENERAL FEATURES – multirange ( 8 for voltage, 8 for current ) – RMS contemporaneous acquisitions of: voltages, currents, frequency, cosj, powers, energies … – accuracy 0,5 – 2 pulses outputs for energy and alarms – memorization of max. powers for every ¼ of hour – RS485 serial insulated interface – scratch-resistant membrane touch switches – secret access code – plumbable splashproof lens cover – modular execution (6 DIN modules)
GENERAL FEATURES – multirange ( 8 for voltage, 8 for current ) – RMS contemporaneous acquisitions of: voltages, currents, frequency, cosj, powers, energies … – accuracy 0,5 – scratch-resistant membrane touch switches – secret access code – plumbable splashproof lens cover – modular execution (6 DIN modules)
GENERAL FEATURES – multirange ( 8 for voltage, 8 for current ) – RMS contemporaneous acquisitions of: voltages, currents, frequency, cosj, powers, energies … – accuracy 0,5 – 2 pulses outputs for energies – scratch-resistant membrane touch switches – secret access code – plumbable splashproof lens cover – modular execution (6 DIN modules)
GENERAL FEATURES Overall dimensions: 60 x 82 x 45 mm Highest system voltage: 0.72 kV Fixing systems: – on DIN Rail. – by fixing brakets. Weight: about 0.3 Kg On request: Protection of the secondary terminals
GENERAL FEATURES Overall dimensions: 56 x 72 x 45 mm Highest system voltage: 0.72 kV Fixing systems: – by fixing brakets. Weight: about 0.3 Kg
GENERAL FEATURES Overall dimensions: 110 x 111 x 80 mm Highest system voltage: 0.72 kV Fixing systems: – by fixing brakets. Weight: about 0.5 Kg On request: Sealable protection of the secondary terminals
Overall dimensions: 97 x 78 x 100 mm Frequency: 50 – 60 Hz Rated secondary voltage: 100 V Rated voltage factor: 1.2 continuous Highest system voltage: 0.72 kV up to 600V 1.44 kV up to 1000V One minute test voltage between primary and secondary: 3kV up to 600V, 6kV up to 1000V
Overall dimensions: 54 x 62 x 46 mm Frequency: 50 – 60 Hz Rated secondary voltage: 100 V Rated voltage factor: 1.2 continuous Highest system voltage: 0.72 kV up to 600V 1.44 kV up to 1000V One minute test voltage between primary and secondary: 3kV up to 600V, 6kV up to 1000V
Overall dimensions: 121 x 83 x 119 mm Frequency: 50 – 60 Hz Rated secondary voltage: 100 V Rated voltage factor: 1.2 continuous Highest system voltage: 0.72 kV up to 600V 1.44 kV up to 1000V One minute test voltage between primary and secondary: 3kV up to 600V, 6kV up to 1000V
Overall dimensions: 84 x 69 x 91 mm Frequency: 50 – 60 Hz Rated secondary voltage: 100 V Rated voltage factor: 1.2 continuous Highest system voltage: 0.72 kV up to 600V 1.44 kV up to 1000V One minute test voltage between primary and secondary: 3kV up to 600V, 6kV up to 1000V
Overall dimensions: 165 x 105 x 123 mm Frequency: 50 – 60 Hz Rated secondary voltage: 100 V Rated voltage factor: 1.2 continuous Highest system voltage: 0.72 kV up to 600V 1.44 kV up to 1000V One minute test voltage between primary and secondary: 3kV up to 600V, 6kV up to 1000V
نمایش 21–40 از 50 نتیجه