THREE PHASE ACTIVE AND REACTIVE POWER TRANSDUCERS BALANCED LOAD, 3 WIRES WITHOUT NEUTRAL
THREE PHASE ACTIVE AND REACTIVE TRANSDUCERS BALANCED LOAD, 4 WIRES WITH NEUTRAL
3phase active transducer
power:44-130 Vac / 70-240 VDC
Input:110 Vac- 1Aac
Alternated Voltage Transducer
power:44-130 Vac / 70-240 VDC
Input:110 Vac
Product Description PARAMETERS : Ph-N Voltage , Current (30A direct or …/CT), Power Factor, Apparent Power, Active Power, Reactive Power, Frequency, Active Energy (resectable capacity), Reactive Energy (resectable capacity), Partial Hourmeter (resectable capacity), Acoustical pre-alarm Usable as PRIORITY RELAY 16A , Motor Protection, Overload, Anomaly of Frequency, Low-High Consuption, Not Presence of phase, Min Voltage Power Supply 230V 50/60 Hz Voltage Input Max 300V Current Input Max 1000/5A Frequency 45-65Hz Dimensions 2DIN Display 2 Display of 3 digit each
Product Description PARAMETERS : Ph-N Voltage, Ph-Ph Voltage, Current, Power Factor, Apparent Power, Active Power, Reactive Power, Frequency, Active Energy, Reactive Energy, Partial Hourmeter, Total Hourmeter, Sequence of phases, Power Supply 230V 50/60 Hz / P1 (22..36VAC e 19..70VDC) / P2 (44..130VAC e 70..240VDC) Voltage Input Max 500V Current Input Max 6000/5A Frequency 45-80Hz Dimensions 6DIN, 96×96 Display 6 Display of 3 digit each Serial Output RS485 (only for “485” models) Burden 4VA Memory EEPROM Protocol Modbus
Product Description. Burden 3VA; Operating Frequency 45-65Hz; Class 1,5; Weight (Kg) 0,50; Direct Input 600V; Soglie Allarme 2; Dimensions 96×96 mm.
Instrument provided with switch, low voltage, for 3 phase-phase and 3 phase-neutral voltage L1N-L2N-L3N/L1L2-L2L3-L1L3
Product Description Current AC , DC Regulation Minimum, Maximum Input <2A , between 2 and 5A , between 5 and 10A / <1mA , between 1 and 10mA , between 10 and 20mA Burden 2W Power Supply 230, P1(22…36VAC/19…70VDC), P2(44…130VAC/70…240VDC) Precision Class 5% Output Relay 16A 250V Hysteresis 1-45% Delay Time 1-30 sec. Calibration 30-100% Overloading 2 In for 10 sec. Dimensions 3DIN
Product Description Current AC , DC Power Supply 230VAC, P1(22…36VAC , 19…70VDC), P2(44…130VAC, 70…240VDC) Accuracy Class 0,5 Selectable Input 1A, 5A Selectable Output 1,5,10V, 1,5,10,20,4-20mA Dimensions 3DIN
Product Description Earth Leakage Control and monitoring provide the protection required against indirect contacts and risk of fire Type A – AC Trip Current Adjustment 30,50,100,150,230,300,350,500mA 1,2,3,5,10,20,30A Time Delay Adjustment 0-0,25-0,5-1-2-3-4-5-6-7-8-10 Dimensions 1DIN, 3DIN, 4DIN, 48×48, 72×72, 96×96 Power Supply 230VAC, PD1(22…36VAC,19…70VDC), PD2(44…130VAC,70…240VDC) Output NC-C-NO 10A 250V
نمایش 1–20 از 63 نتیجه